ECOM America Ltd., the leader in portable emission / combustion analyzers manufactures models for many applications. From single gas Oxygen and Carbon Monoxide analyzers for flue gas testing to multi-gas analyzers measuring Oxygen, Carbon Monoxide, Nitric Oxide, Nitrogen Dioxide, Sulfur Dioxide, & Hydrocarbons offered in several configurations, we have instruments for most combustion applications. Several models are approved and recognized by Regional, State, and Federal Environmental and Air Quality Regulatory Agencies.
Proper Sample Conditioning is an important function of portable electrochemical sensor based analyzers. What truly sets ECOM analyzers apart from our competitors is the importance we have placed on sample conditioning and gas delivery techniques. Ensuring a consistently cool and dry gas sample to the sensors is crucial to long term reliability and accuracy of the analyzer. Our maintenance analyzers incorporate a high flow pump and radiated gas cooler / moisture trap. The moisture collects in a condensate bowl, and can be automatically or manually drained, depending on the model. Our compliance level models offer sample conditioning features not found on any other brand of portable emission analyzers available today. Along with high flow pumps, recent modifications and options continue to assure accurate and reliable emission testing data.
Heated Sample Lines: A custom length, self-regulating heated line is now available for use with the GAMMA, A-PLUS, J2KN, KL, and SG+ models. This line operates on 110 VAC, and has internal temperature controls to maintain the gas temperature above the dew point, eliminating condensation in the sample line.
Thermoelectric Peltier Cooler: After travelling through the heated line, the sample gas enters the temperature controlled cooler, (maintained at 40 - 45 deg. F), where the moisture in the gas quickly condenses and is trapped in the water trap bowl.
Peristaltic Pump: Automatically removes condensate from the water trap, minimizing the sample gas / moisture contact.
Flow Meter: Adjustable flow meters are now installed in-line, so operators are assured consistent flow of gas between calibrations and testing.
Pressure Control is regulated by ECOM's patented internal gas manifold system. All ECOM analyzers use a proprietary sensor manifold and pressure control device to deliver a precise sample of gas to each individual sensor.
Because the sample gas is properly conditioned and controlled prior to introduction to the sensors, the typical life of the sensors in ECOM analyzers is usually much longer, calibration stability much better, and sensor stability more consistent, than that of our competitors, resulting in lower lifetime maintenance costs.
Other unique features of ECOM analyzers:
Electronic Temperature Compensation over the full operating range
Thermoelectric gas cooler and automatic moisture removal
Anti cross- interference software
Large Zoom display w/ Contrast control
Automatic CO over-range protection
Automatic switching of CO measurement ranges
Pressure Transducer for draft & backpressure measurement
Convenient NOx calculation displayed
Programmable Oxygen correction
Programmable setting for PPM, #/mBtu, mg/m3
Automatic purge prior to shutdown
Windows based Data Acquisition Software with real time display of measured parmaters and mass emissions (g/bhp, lbs/hr, tons/yr, lbs/mmBtu) using EPA Method 19. Follows current protocols for error proof report generation.
Service & Maintenance Analyzers:
ECOM 200
Handheld Oxygen analyzer for light boiler / burner set-up and AFR adjustments on natural gas engines.
ECOM CN
Compact, yet full featured, analyzer for any combustion applications such as boiler/burner set-up as well as engine analysis. O2,CO, Temperature, plus CO2, Efficiency, Excess Air and Oxygen Correction calculations.
ECOM AC
4-6 gas analyzer for complete boiler / burner and engine testing and service applications. Calculated parameters, integral printer, RS232, etc. OC or OV, plus any combination up to 7 choosing from C, V, N, X, S, H, IR
Compliance Level Analyzers:
ECOM GAMMA
Stand-alone gas sample conditioner, self-regulating heated sample line / probe head, and refrigerated gas cooler w/ peristaltic pump.
ECOM J2KN
Up to 5 gas analyzer, with wireless remote control & display, plus wireless data transmission using ECOM's Advanced DAS software. Features high flow pump, peltier cooler and optioanl heated sample line. EPA Compliance Level Analyzer. Available with standard NOX or LOW NOX sensor range.
ECOM A-PLUS
Up to 5 gas analyzer, same features as AC, plus heated sample line / peltier cooler. EPA Compliance Level Analyzer. OC or OV, plus any combination up to a total of 5 choosing from C, V, N, X, S, H.
ECOM KL
Up to 6 gas analyzer with electronic sample conditioning, extensive data processing and automatic sampling cycles. EPA Compliance Level Analyzer. OC or OV, plus any combination up to 6 choosing from C, V, N, X, S, H, IR
ECOM SG+
Up to 7 gas analyzer with superior sample conditioning, (heated sample line, gas cooler, active moisture removal), data processing, automatic sampling cycles, long term measurement capability. EPA Compliance Level Analyzer. OC or OV, plus any combination up to 7 choosing from C, V, N, X, S, H, IR.
Calibration Gas:
Calibration Gas
ECOM offers a wide range of calibration gas concentrations suitable for emission testing and protocols